Running a pure fluid flow ========================= With HemoCell it is possible to run a pure fluid flow, without any cells present within the domain. This is technically the same as just running a fluid simulation with Palabos. The simplest way to remove all the cells is to set the number of cells in the ``CELL.pos`` files to zero (first line). Or to remove the ``addCellType`` and all subsequent functions that request that specific cell-type (such as ``setOutputs``) from the ``case.cpp`` file. However, this still leaves a small overhead as the function for the material model are still called (although little work is done inside them as there are no cells). This can be circumvented by replacing .. code-block:: c++ hemocell.iterate() with .. code-block:: c++ hemocell.lattice->collideAndStream(); hemocell.iter++; within the ``case.cpp`` file .. _other_topics:csv-output: