Capillary flow

The example in examples/capillary presents two example cases where a single white blood cell (WBC) is flowing through a narrow capillary. The considered channels have smaller diameters compared to the WBC, requiring the cell to undergo deformations as it squeezes through the channels.

Two variations are presented: a wedge-like geometry and a bifurcating channel, with their details given in the subsequent sections. The code for both examples is presented in a single main file examples/capillary/capillar.cpp where an enumerated type Scenario is presented to toggle between both cases. To run a specific example, you can modify the scenario definition at the top of the file to match with the desired example case.

const auto scenario = Scenario::Wedge
const auto scenario = Scenario::Bifurcation

The specific code of each example is given in wedge.cpp and bifurcation.cpp for the Wedge and Bifurcation scenarios respectively. After selecting a scenario, the compilation steps are identical to other the example cases, see compilation.

Note

Both examples require that the white blood cell’s solid core is smaller than the gaps between the solid domains, i.e. the gap between the wedges or the diameter of the bifurcating capillaries. This ensures that the WBC can undergo sufficient deformations to squeeze through the channels. The size of the solid core can be specified through the <MaterialModal><coreRadius> parameter in the WBC_wedge.xml, WBC_bifurcation.xml configuration files.

Squeezing through a gap (Scenario::Wedge)

The first example (Scenario::Wedge) considers a single white blood cell (WBC) flowing through a narrow gap between two triangular wedges. Since the outer diameter of the WBC is larger than the considered gap in the solid geometry, the cell is compressed and squeezes through the gap. As the cell passes through the gap, the distance to the solid regions increases and the cell relaxes again. For reference material, please refer to Figure 3 of the corresponding publication by Lykov et al. (2017).

Cell flowing through wedge

A white blood cell (WBC) as it flows through a wedge-like geometry. The cell is shown in four different configurations as it passes through the gap. Sinigificant deformations are observed that relax again once the cell has fully passed the smallest diameter of the gap. The shown velocity magnitude (blue to red) corresponds to the second deformation, i.e. when the cell passes through the smallest diameter.

A bifurcating capillary (Scenario::Bifurcation)

The second example (Scenario::Bifurcation) considers a single white blood cell (WBC) flowing through one of two capillaries. The domain starts with a single inlet that branches in two capillaries of equal length and cross-section. Similar to the wedge-like geometry (Scenario::Wedge) the cell is smaller than the diameter of the capillary, resulting in significant cell deformations.

Cell flowing through bifurcation

A white blood cell (WBC) as it passes into one of two identical capillaries past the bifurcation. The cell is show for four different configurations as it passes through the channel. Significat deformations are observed when the cell squeezed through the bottom capillary. The velocity magnitude is depicted (blue to red) for the second-last position of the WBC.

Adding repulsive forces

Both examples are evaluated without any repulsive forces between the cells and the walls of the channel. To include repulsive forces, please refer to advanced case regarding repulsive forces.